• Skip to primary navigation
  • Skip to main content
Get a quote
hello@okoHaus.co.uk | 01473 550514
okoHaus UK Limited logo

okoHaus UK Limited

  • Home
  • Products
    • Internorm Windows & Doors
    • Velfac 200 Energy Windows & Doors
    • Velfac Classic Windows & Doors
    • Velfac Ribo Windows & Doors
    • Rationel Alu Clad Timber Windows
    • Rationel Timber Windows and Doors
    • Solarlux Cero Sliding Doors
    • Solarlux Bi-Fold Doors
    • Solarlux Glass Box Extensions
    • Bel’M Doors
    • Nimly Smart Locks
    • Sealants and Air Tightness
    • Centor Insect Screens
  • Brands
    • Velfac
    • Rationel
    • Internorm
    • Solarlux
    • Bel’M
    • Nimly
    • Centor
  • Services
  • Installations
  • Showroom
  • Gallery
  • Downloads
  • Sustainability
  • About us
    • Meet The Team
    • Careers at okoHaus
    • FAQs
    • Environmental Policy
    • Privacy Policy
    • Cookie Policy (UK)
    • Complaints Procedure
    • Terms and Conditions of Supply
  • Blog
    • Case Studies
    • Support
    • News
  • Contact Us
  • Show Search
Hide Search
Home » Important updates to building regulations for refurbishment projects

Important updates to building regulations for refurbishment projects

February 23, 2022 ·

Long overdue changes are afoot in the UK building regulations, which will impact windows and doors for both new builds and refurbishment projects.

The UK Government will introduce the new Future Buildings Standard by 2025. This standard aims to future-proof new homes by increasing energy efficiency standards.

In the meantime, in an attempt to transition to the Future Buildings Standard, some interim changes are to be introduced on 15th June 2022.

The changes affecting windows and doors for refurbishment projects are focused on Building Regulations Approved Document F: Ventilation and Approved Document L: Conservation of Fuel and Power.

kitchen windows

Approved Document F: Ventilation

The construction industry is starting to realise that ventilation, along with airtightness, is much more important for building health and performance, and therefore, more consideration should be given to ventilation.

Building regulations, administered via our Fensa certification, previously required that we replace trickle ventilators like for like. In other words, if we are replacing a window with a trickle vent, the new window should also have a trickle vent. Fairly simple. The client also had the option to ‘opt out’ of trickle vents. The new requirements go a bit further and require a bit more thought.

The new requirements specify an equivalent area for trickle vents, depending on the room type:

For habitable rooms and kitchens, the equivalent area is 8,000mm2.

For bathrooms, the equivalent area is 4,000mm2.

Each trickle vent in our systems typically achieves 2,500mm2, so in a habitable room, we would need four trickle vents and two trickle vents in a bathroom. This is generally achievable, depending on the size and design of the windows/doors being replaced.

Things are slightly different if your property has a continuous mechanical extract ventilation system. In that case, we are only required to have trickle vents with an equivalent area of 4,000mm2 in windows not in wet rooms (i.e., kitchens, bathrooms and utility rooms).

It is worth noting that if adopting the minimum equivalent areas set out is not technically feasible, trickle vents with the closest possible equivalent area can be used. Additionally, other ventilation strategies can be employed if they meet the requirements.

wide open window

Approved Document L: Conservation of Fuel and Power

The changes to building regulations Part L are where things will get interesting for the replacement window industry. The minimum thermal performance of windows and doors is increasing, pushing refurbishment windows and doors ahead of new-build windows and doors.

Previously, to comply with building regulations for thermal performance, replacement windows and doors needed to achieve a whole window/door U value of 1.6W/m2K. Our blog post Weighing up double versus triple glazing outlines the importance of understanding relative U values when comparing window and door products. Basically, the lower the U value, the less energy is escaping from the building, and therefore, the better the window/door’s performance.

The changes, effective 15 June 2022, will require that windows and doors achieve a whole window/door U value of 1.4W/m2K. Interestingly, replacement timber windows will only need to achieve 1.6W/m2K, a move that we believe will allow traditional timber sliding sash windows to be replaced close to like for like.

Many aluminium, UPVC, and even aluminium/timber composite window and door systems will struggle to achieve 1.4W/m2K. At the time of writing, it seems that much of the industry has its heads buried deep underground, and many system manufacturers don’t seem to have products that will genuinely be able to keep up with the changes. Some parts of the industry are actively campaigning to delay the changes.

For our products, we will no longer be able to use the Velfac V200 double-glazed system for refurbishment projects, except in exceptional circumstances. For example, the windows are very simple and large, with a bespoke, project-specific U value calculation.

Our Rationel and FT-Vilstal systems have no problems meeting the improved thermal performance requirements with double glazing, so they should start to become a more attractive value proposition for more of our customers.

large patio doors

Given the UK housing stock is widely reported to be the worst-performing in Europe, it’s right that the immediate focus is on improving standards for refurbishment projects. This will at least quickly stop the continued low-performance renovation practice, thereby avoiding worsening the problem. And we believe it’s right, long overdue, that the government should legislate to push the construction industry to improve performance.

Only by raising the already very low bar set will consumers be protected from making poor choices in a significant investment in their property.

Building Regulation Changes FAQs

What are building regulations?

Building regulations are the legal minimum standards that all building projects must adhere to. From a windows and doors perspective, we are generally concerned with building regulations around security, safety, thermal performance, and overheating.

Do I need building regs?

Yes, all building projects must comply with building regulations. They provide important guidance to make sure buildings achieve a safe and healthy environment.

Are replacement windows exempt from building regulations?

No; like all building works, replacement window projects must meet building regulations. okoHaus are Fensa registered, which means we are trusted to ‘self certify’ for building regulations compliance. For most simple replacement window projects, this means you would not need to arrange a building control inspection.

Last Updated on February 19, 2026

Related Posts:
  • Weighing up double versus triple glazing
  • Frequently Asked Questions about Eco-Friendly…
  • Taking you through our order process
  • Why Sustainability Matters to Us
  • Bel'M
  • Meet The Team

News

Authorised Velfac, Rationel, Solarlux, Internorm, Bel'M and Nimly distributor

okoHaus UK Limited
The Beet House, Home Farm
Main Road, Woolverstone
Suffolk, IP9 1AJ
United Kingdom
hello@okoHaus.co.uk | 01473 550514
Company No: 12582621

Copyright © 2026 okoHaus UK Limited

  • Environmental Policy
  • Privacy Policy
  • Terms and Conditions of Supply
  • Complaints Procedure
  • Contact
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}